PH - CVS and Respiratory

Exit

Question 1 of 1

  Time Left


0 [{"id":508168,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"25855 \u2013 The pulse oximeter 1: is unaffected by the level of carboxyhaemoglobin\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":8,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508164,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"15413 \u2013 Forces which are acting on the lung at the end of normal expiration include 1: elastic tendency of the thoracic cage to sustain expansion\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":4,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508174,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"25794 \u2013 Patients for whom mask oxygen therapy is inadequate 3: may not show low oxygen saturation or low pulse oximetry until at a late stage\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":14,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508163,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"15418 \u2013 With respect to forced expiratory flow volume curves 4: effective driving pressure for expiration is alveolar minus intrapleural pressure\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":3,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508170,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"25855 \u2013 The pulse oximeter 3: may be inaccurate in hypovolaemia\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":10,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508167,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"15413 \u2013 Forces which are acting on the lung at the end of normal expiration include 4: a negative intrapleural pressure\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":7,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508166,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"15413 \u2013 Forces which are acting on the lung at the end of normal expiration include 3: elastic tendency of the lung to collapse\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":6,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508172,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"25794 \u2013 Patients for whom mask oxygen therapy is inadequate 1: are often tachypnoeic\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":12,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508162,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"15418 \u2013 With respect to forced expiratory flow volume curves 3: features of the curve are due to dynamic airway collapse\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":2,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508169,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"25855 \u2013 The pulse oximeter 2: is a useful indicator of PaO2\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":9,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508171,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"25855 \u2013 The pulse oximeter 4: may be used to measure pulse rate\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":11,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508160,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"15418 \u2013 With respect to forced expiratory flow volume curves 1: expiratory flow declines with decreasing lung volume\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":0,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508161,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"15418 \u2013 With respect to forced expiratory flow volume curves 2: maximum expiratory flow rate is independent of effort at mid to low lung volumes\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":1,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508165,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"15413 \u2013 Forces which are acting on the lung at the end of normal expiration include 2: surface tension effects at the alveolus tending to produce collapse\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":5,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null},{"id":508173,"quiz_id":"26014","answer_id":null,"answerType_id":"0","created_at":"2018-07-25 03:14:10","updated_at":"2018-07-25 03:14:22","questionName":"25794 \u2013 Patients for whom mask oxygen therapy is inadequate 2: show distress, dyspnoea, exhaustion, sweating and confusion\u00a0","questionTimeSeconds":"0","questionTimeMinutes":"15","questionImagePath":null,"position":13,"explanation":null,"question_score_id":null,"lang":null,"questionAudioPath":null}]
508168
0
900
block

25855 – The pulse oximeter 1: is unaffected by the level of carboxyhaemoglobin 

Select the correct answer(s).  

(0/0)








508164
0
900
none
508174
0
900
none
508163
0
900
none
508170
0
900
none
508167
0
900
none
508166
0
900
none
508172
0
900
none
508162
0
900
none
508169
0
900
none
508171
0
900
none
508160
0
900
none
508161
0
900
none
508165
0
900
none
508173
0
900
none